BLT M1000 Vet 8" Multi-Parameter Monitor

$ 1499.98 Sale

High Quality, Very accurate, Reliable Monitor

M1000 Vet Monitor by BLT Biolight is compact and lightweight, features a touchscreen, and is battery powered. Comes ready to work with the veterinary accessories you need. 

Standard Configuration

  • Rechargeable lithium-ion battery
  • 8” TFT LCD touch screen 
  • Lightweight and compact portable design 
  • Standard parameters including 3/5 leads ECG, HR, RESP, NIBP, SpO2, PR, TEMP 
  • Triple and Multi-level Sound/Light/Screen alarm 
  • Large capability battery with over 6 hours of continuous usage 
  • 168 hours trend data storage 
  • 1000 groups NIBP measurement review

Physical & Power specifications  

  • Dimension: 220mm(H)×180mm(W)×90mm(D) 
  • Weight: <2 kg 
  • Power Voltage: AC 100V-240V 50Hz/60Hz 
  • Input current: 1.5A-0.7A

Battery 

  • Type: 11.1VDC/2200mAh
  • Rechargeable Lithium ion battery 
  • Operating time: Under the normal use and full charge: ≥6 hours 
  • Indicator of battery capability

Display

  • Size: 8″ Color TFT LCD touchscreen 
  • Resolution: 800×600 pixels

Data Storage

  • Trend data: 168 Hours 
  • NIBP measurement review: 1000 Groups 
  • Alarm Events: 128 Groups 
  • ARR event: 128 Groups

ECG

  • Lead Mode: 3/5 leads ECG input 
  • Lead selection: I, II, III, aVR, aVL, aVF, V 
  • Gain: 2.5 mm/mV (×0.25), 5 mm/mV (×0.5)
  •  10 mm/mV (×1), 20 mm/mV (×2)
  •  40 mm/mV (×4), Auto 
  • Input impedance: ≥5.0 MΩ 
  • Animal leakage current: < 10 uA 
  • CMRR: Diagnostic mode ≥ 89 dB
  • Monitor mode ≥ 105 dB 
  • Surgery mode ≥ 105 dB 
  • Baseline recovery: Monitor mode: ≤ 3 s
  • Surgery mode: ≤ 1 s 
  • Sweep speed: 12.5 mm/s, 25 mm/s, 50 mm/s

HR 

  • Measurement Range: Large animal: 10 bpm to 300 bpm 
  • Normal and small animal: 10 bpm to 350 bpm 
  • Accuracy: ±1% or ±1 bpm, whichever is greater

RESP 

  • Method: Thoracic impedance 
  • Measuring impedance range: 0.2Ω ~3Ω 
  • Accuracy: ±2 rpm

NIBP 

  • Measurement way: Automatic Oscillometry 
  • Measurement range(mmHg): SYS 30~270 mmHg 
  •  DIA 10~220 mmHg  
  •  Map 20~235 mmHg 
  • (Large animal, normal and small animal have different measurement range) 
  • Pressure Accuracy: Static: ±3 mmHg 
  • Clinic: Average error: ±5 mmHg, 
  • standard deviation: ≤8 mmHg 
  • Unit: mmHg, kPa 
  • Cuff pressure range: 0 mmHg ~ 280 mmHg
  • Initial inflation pressure:
  • Large animal default: 160 mmHg 
  • Mid animal default: 130 mmHg 
  • Small animal default: 75 mm 
  • Overpressure Protection(Hardware and software double protections): 
  • Large animal: (297±3) mmHg Normal animal: (147±3) mmHg 
  • Small animal: (252±3) mmHg 
  • Alarm Indication: Three levels of alarming: Audible-visual alarming 
  • Alarming with blinked data and parameters Text prompts 
  • Work mode: Large animal: Single, Cycle, STAT 
  • Normal animal: Single, Cycle, STAT 
  • Small animal: Single, Cycle

BLT SpO2 

  • Measurement Range: 0%~100% 
  • Resolution: 1% 
  • Accuracy: At 70~100%, ±2% At 0~69%, unspecified 
  • Alarm range: 85% to 100%, high/low limit can be adjusted continuously
  • Average time: Normal:8s, slow: 16s,fast: 4s 
  • Anti-interference: Anti-interference of movement Anti-interference of electrocautery unit 
  • Resisting low perfusion capability 
  • Pitch Tone: With

PR 

  • Measurement Range: 20~250 bpm 
  • Resolution:1 bpm Accuracy: ±1% or ±1 bpm, whichever is greater 
  • Alarm range: 0 bpm~300 bpm, high/low limit can be adjusted continuously 
  • Recovery time after defibrillation: <10s

TEMP 

  • Measurement way: Thermal resistance way 
  • Measurement Range: 0.0~50.0℃ (32℉~122℉) 
  • Unit : Celsius (℃), Fahrenheit (℉) 
  • Resolution: 0.1℃ 
  • Accuracy: At 45.1~50.0℃, ±0.3℃ (including the probe) 
  • At 25.0~45.0℃, ±0.2℃ (including the probe) 
  • At 0.0~24.9℃, ±0.3℃ (including the probe)