Animal Patient Monitor Biolight BLT-M9000

$ 1999.00 Sale

Multi-Parameter Animal Monitor

FDA approved for measuring vital signs. For use in hospitals or clinics. Use to monitor patients ECG, respiration breathing, NIBP (non-invasive blood pressure), pulse rate, SPo2, temperature, IBP, multi-gas/o2 parameters.

Features

  • 12.1’’ LCD display, high resolution
  • Large number display for long distance vision
  • Digital SPO2 technology offers anti-motion and anti-low perfusion funtions
  • Up to 66 beds network capacity to connect with HIS 168 hours tabular and graphic trends & data storage
  • Drug dose calculation
  • OXYCRG softwa12.1’’ LCD display, high resolution,
  • Large number display for long distance vision
  • Digital SPO2 technology offers anti-motion and anti-low perfusion funtions
  • Up to 66 beds network capacity to connect with HIS 168 hours tabular and graphic trends & data storage
  • Drug dose calculation
  • OXYCRG software
  • Bed to bed view

Specifications

  • Safety: IEC60601 (GB9706)
  • Dimension: 318mm (W) x 264mm (H) x 152mm(D)
  • Power Supply: 100~240V; AC: 50~ 60 Hz
  • Alarm Indication: Visual and audible alarm
  • 1800 groups of alarm events review
  • Application: Adult, Pediatric and neonate 
ECG
  • Leads: I, II, III, aVR, aVL, aVF, V
  • Gains: 2.5mm/mV, 5mm/mV, 10mm/mV, 20mm/mV, 40mm/mV, auto Input impedance: =5MO (d.c.~60Hz)
  • Common Mode Rejection Ratio: =85dB(diagnostic mode) =105dB(monitoring & surgica mode) Bandwith: 0.5-40Hz (monitoring mode) 0.05-120Hz(diagnostic mode) 1-25Hz (surgical mode)
  • Protection: Segregation breakdown voltage 4000VAC, 50/60Hz Resistant to high-frequency electrotome, myoelectricity, AC, drifting interference
  • Indication of Detachment of electrodes: Available
  • Playback of Cardiogram: Available
  • Scanning Speed: 12.5mm/s, 25mm/s, 50mm/s
  • Heart Rate Range:10-300BPM
  • Accuracy: ±1BPM
  • ECG waveform playback: 30 minutes
NIBP
  • Method: Automatic oscillometric
  • Operation Modes: Singles (manual), Cycle (automatic), Rapid (continuous)
  • Measurement: Systolic pressure/diastolic pressure/mean pressure
  • Range: Adult: 10-270mmHg
  • Pediatric: 10-235mmHg
  • Neonate: 10-135mmHg
  • Unit: mmHg / Kpa selectable
  • Auto Measurement: 1,2,3,4,5,10,15,20,30,45,60,90 minutes, 2,4,8, hours
  • 1000 groups of NIBP measuring data review

RESP

  • Method: Impedance Measurement
  • Measuring Range: 0-120bpm
  • Alarm Limit: 0-120bpm, upper and lower limit continuously adjustable
  • Apnea alarm: Available
  • BLT Digital SPO2 (Pulse Oximetry)
  • Range: 0-100%
  • Accuracy: ±2% (70%~100%);
  • ±3%(35%~ 69%)
  • Unspecified (0~34%)
  • Range & Accuracy of Pulse Rate: 20~250BPM ± 1BPM

TEMP Channel 

  • 2 channels
  • Range: 0~50?
  • Unit : Celsius, Fahrenheit
  • Resolution: 0.1?
  • Accuracy: ±0.1? (25?~50?)
  • Alarm Range: 0~50?

IBP Channel

  • 2 channels
  • Range: -50~300 mmHg
  • Resolution: 1 mmHg
  • Accuracy: ±2 mmHg (±2%) without probe ±4 mmHg (±2%) with probe
  • Unit: mmHg
  • Kpa Converter sensitivity: 5 uV/V/mmHg
  • Names of pressures: ART/PA/CVP/LAP/RAP/ICP
Optional
  • EtCO2 (side stream)
  • Method: Infrared spectrum
  • Range: 0.0-13.1%
  • Resolution: 1 mmHg (0.1%)
  • Accuracy: 5% EtCO2