Multi-Parameter Animal Monitor
FDA approved for measuring vital signs. For use in hospitals or clinics. Use to monitor patients ECG, respiration breathing, NIBP (non-invasive blood pressure), pulse rate, SPo2, temperature, IBP, multi-gas/o2 parameters.
Features
- 12.1’’ LCD display, high resolution
- Large number display for long distance vision
- Digital SPO2 technology offers anti-motion and anti-low perfusion funtions
- Up to 66 beds network capacity to connect with HIS 168 hours tabular and graphic trends & data storage
- Drug dose calculation
- OXYCRG softwa12.1’’ LCD display, high resolution,
- Large number display for long distance vision
- Digital SPO2 technology offers anti-motion and anti-low perfusion funtions
- Up to 66 beds network capacity to connect with HIS 168 hours tabular and graphic trends & data storage
- Drug dose calculation
- OXYCRG software
- Bed to bed view
Specifications
- Safety: IEC60601 (GB9706)
- Dimension: 318mm (W) x 264mm (H) x 152mm(D)
- Power Supply: 100~240V; AC: 50~ 60 Hz
- Alarm Indication: Visual and audible alarm
- 1800 groups of alarm events review
- Application: Adult, Pediatric and neonate
ECG
- Leads: I, II, III, aVR, aVL, aVF, V
- Gains: 2.5mm/mV, 5mm/mV, 10mm/mV, 20mm/mV, 40mm/mV, auto Input impedance: =5MO (d.c.~60Hz)
- Common Mode Rejection Ratio: =85dB(diagnostic mode) =105dB(monitoring & surgica mode) Bandwith: 0.5-40Hz (monitoring mode) 0.05-120Hz(diagnostic mode) 1-25Hz (surgical mode)
- Protection: Segregation breakdown voltage 4000VAC, 50/60Hz Resistant to high-frequency electrotome, myoelectricity, AC, drifting interference
- Indication of Detachment of electrodes: Available
- Playback of Cardiogram: Available
- Scanning Speed: 12.5mm/s, 25mm/s, 50mm/s
- Heart Rate Range:10-300BPM
- Accuracy: ±1BPM
- ECG waveform playback: 30 minutes
NIBP
- Method: Automatic oscillometric
- Operation Modes: Singles (manual), Cycle (automatic), Rapid (continuous)
- Measurement: Systolic pressure/diastolic pressure/mean pressure
- Range: Adult: 10-270mmHg
- Pediatric: 10-235mmHg
- Neonate: 10-135mmHg
- Unit: mmHg / Kpa selectable
- Auto Measurement: 1,2,3,4,5,10,15,20,30,45,60,90 minutes, 2,4,8, hours
- 1000 groups of NIBP measuring data review
RESP
- Method: Impedance Measurement
- Measuring Range: 0-120bpm
- Alarm Limit: 0-120bpm, upper and lower limit continuously adjustable
- Apnea alarm: Available
- BLT Digital SPO2 (Pulse Oximetry)
- Range: 0-100%
- Accuracy: ±2% (70%~100%);
- ±3%(35%~ 69%)
- Unspecified (0~34%)
- Range & Accuracy of Pulse Rate: 20~250BPM ± 1BPM
TEMP Channel
- 2 channels
- Range: 0~50?
- Unit : Celsius, Fahrenheit
- Resolution: 0.1?
- Accuracy: ±0.1? (25?~50?)
- Alarm Range: 0~50?
IBP Channel
- 2 channels
- Range: -50~300 mmHg
- Resolution: 1 mmHg
- Accuracy: ±2 mmHg (±2%) without probe ±4 mmHg (±2%) with probe
- Unit: mmHg
- Kpa Converter sensitivity: 5 uV/V/mmHg
- Names of pressures: ART/PA/CVP/LAP/RAP/ICP
Optional
- EtCO2 (side stream)
- Method: Infrared spectrum
- Range: 0.0-13.1%
- Resolution: 1 mmHg (0.1%)
- Accuracy: 5% EtCO2