Animal Patient Monitor Biolight BLT-M9000

Multi Parameter Animal Monitor

FDA approved for measuring vital signs. For use in hospitals or clinics. Use to monitor patients ECG, respiration breathing, NIBP (non invasive blood pressure), pulse rate, SPo2, temperature, IBP, multi gas/o2 parameters.

Features

  • 12.1’’ LCD display, high resolution
  • Large number display for long distance vision
  • Digital SPO2 technology offers anti-motion and anti-low perfusion funtions
  • Up to 66 beds network capacity to connect with HIS 168 hours tabular and graphic trends & data storage
  • Drug dose calculation
  • OXYCRG softwa12.1’’ LCD display, high resolution,
  • Large number display for long distance vision
  • Digital SPO2 technology offers anti-motion and anti-low perfusion funtions
  • Up to 66 beds network capacity to connect with HIS 168 hours tabular and graphic trends & data storage
  • Drug dose calculation
  • OXYCRG software
  • Bed to bed view

Specifications

  • Safety: IEC60601 (GB9706)
  • Dimension: 318mm (W) x 264mm (H) x 152mm(D)
  • Power Supply : 100~240V; AC: 50~ 60 Hz
  • Alarm Indication: Visual and audible alarm
  • 1800 groups of alarm events review
  • Application: Adult, Pediatric and neonate

ECG

Leads: I, II, III, aVR, aVL, aVF, V
Gains: 2.5mm/mV, 5mm/mV, 10mm/mV, 20mm/mV, 40mm/mV, auto Input impedance: =5MO (d.c.~60Hz)
Common Mode Rejection Ratio: =85dB(diagnostic mode) =105dB(monitoring & surgica mode) Bandwith: 0.5-40Hz (monitoring mode) 0.05-120Hz(diagnostic mode) 1-25Hz (surgical mode)
Protection: Segregation breakdown voltage 4000VAC, 50/60Hz Resistant to high-frequency electrotome, myoelectricity, AC, drifting interference
Indication of Detachment of electrodes: Available
Playback of Cardiogram: Available
Scanning Speed: 12.5mm/s, 25mm/s, 50mm/s
Heart Rate Range:10-300BPM
Accuracy: ±1BPM
ECG waveform playback: 30 minutes

NIBP

Method: Automatic oscillometric
Operation Modes: Singles (manual), Cycle (automatic), Rapid (continuous)
Measurement : Systolic pressure/diastolic pressure/mean pressure
Range: Adult: 10-270mmHg
Pediatric: 10-235mmHg
Neonate: 10-135mmHg
Unit: mmHg / Kpa selectable
Auto Measurement: 1,2,3,4,5,10,15,20,30,45,60,90 minutes, 2,4,8, hours
1000 groups of NIBP measuring data review

RESP

Method: Impedance Measurement
Measuring Range: 0-120bpm
Alarm Limit: 0-120bpm, upper and lower limit continuously adjustable
Apnea alarm: Available
BLT Digital SPO2 (Pulse Oximetry)
Range: 0-100%
Accuracy: ±2% (70%~100%);
±3%(35%~ 69%)
Unspecified (0~34%)
Range & Accuracy of Pulse Rate : 20~250BPM ± 1BPM

TEMP Channel 

2 channels Range : 0~50? Unit : Celsius, Fahrenheit Resolution : 0.1? Accuracy : ±0.1? (25?~50?) Alarm Range : 0~50?

IBP Channel

2 channels Range : -50~300 mmHg Resolution : 1 mmHg Accuracy : ±2 mmHg (±2%) without probe ±4 mmHg (±2%) with probe Unit : mmHg , Kpa Converter sensitivity: 5 uV/V/mmHg Names of pressures: ART/PA/CVP/LAP/RAP/ICP
Optional
EtCO2 (side stream) Method: Infrared spectrum Range: 0.0-13.1% Resolution : 1 mmHg (0.1%) Accuracy : 5% EtCO2,